EDS-MD Wired IoT Gateway for Medical Devices

EDS-MD Wired IoT Gateway for Medical Devices

Certified Multi-Port Wired IoT Gateway for Medical Devices

  • UL and IEC-60601 compliance provides galvanic port isolation to protect connected medical devices
  • Securely connect any medical device with a serial interface to the network using enterprise-level SSL and SSH
  • Simple set up and configuration with industry-standard management tools including Web, CLI, XML powered by MACH10
  • Gigabit Ethernet offers increased bandwidth for higher performance
  • Available with 4, 8 or 16 ports

Description

Overview for EDS-MD

Manage Visibility into Medical Assets

The medical industry utilizes many connected devices and assets. A majority of these devices are critical to the operation of the medical enterprise, for example, patient monitors. The EDS-MD can be integrated into the medical enterprise’ network and enable visibility into these devices from anywhere, anytime.

Manage Mission-Critical Data Securely

The transport of sensitive information to and from remote device servers over the Internet demands the highest level of security. With Lantronix’ proprietary Secure Com Port Redirector™ virtualization software, existing serial port applications can work with EDS-MD without any code modifications. Virtual COM ports can be mapped to EDS-MD and encrypted at both ends of communication.

Manage Assets and Data Locally or Remotely

Management of any device and data requires fault-tolerance. EDS-MD empowers authorized IT staff to access and monitor devices and data anywhere, anytime. In addition, the EDS-MD goes beyond the IEC-60601 requirement, as it provides galvanic isolation on all ports to ensure the highest levels of safety and fault-tolerance. Should a grounding issue ever occurs, the operation of EDS-MD or other connected devices will not be affected.

High-Performance Wired Connectivity

The EDS-MD offers 4, 8 or 16 individually isolated RS-232 serial ports with a Gigabit (10/100/1000Mpbs) network interface. The configuration and setup of the EDS-MD is simple with industry-standard management tools including integrated Web and CLI interfaces along with XML support. For best overall operation, it can be managed by Lantronix Gateway Central powered by MACH 10.

Specifically designed for the medical industry, the UL and IEC-60601 compliant EDS-MD provides mission-critical device connectivity, allowing remote access and management of virtually any electronic or medical device.EDS-MD offers the benefit of 4, 8 or 16 individually isolated RS-232 serial ports with a Gigabit (10/100/1000Mpbs) network interface. Going above and beyond the IEC-60601 requirement, EDS-MD provides galvanic isolation on all ports to ensure the highest levels of safety. If a grounding problem occurs, the operation of EDS-MD or other connected devices will not be affected.

With Lantronix’ proprietary Secure Com Port Redirector virtualization software, existing serial port applications can work with EDS-MD without any code modifications. Virtual COM ports can be mapped to EDS-MD and encrypted at both ends of the communication, allowing the transport of sensitive information to and from remote device servers over the Internet with the highest level of security.

Set up and configuration of EDS-MD is simple with industry-standard management tools including Web, CLI, XML and Lantronix Gateway Central powered by MACH10.

EDS-MD – Certified Multi-Port Wired IoT Gateway for Medical Devices

IMG_diag_hospital-eds-md

 

Additional information

Key Features

Features & Specifications for EDS-MD
Standards
IEEE 802.3
IEEE 802.3u
IEEE 802.3ab
USB 2.0
Hardware
600MHz ARM 11 processor
8 MB Flash
4 GB SD Card (internal only)
256 MB SDRAM
Real Time Clock with Battery back-up
Onboard Thermal Sensor
Physical Interface
4/8/16 RJ45 (DTE) Serial Connectors
RS-232 Interface
Data rates – up to 921 Kbps
ESD Protection – 15kV
Circuit and port isolation – 1.5KVAC
2 USB Host ports – USB-A receptacle connectors
Output Capability = 0.5A
Circuit and port isolation – 1.5KVAC
1 Ethernet port – RJ45 connector^
10/100/1000Mbps
Autosensing MDI/MDIX
Full/half duplex
Circuit and port isolation – 1.5KVAC
1 Reset Button
^ 2 additional Ethernet ports enabled with future firmware release.

Protocols
• DHCP Client, DHCP Server, DHCPv6 Client
• uPnP (Discovery), LCAP (77FE), Telnet, FTP, HTTP(S)
• IPv4/IPv6, TCP, UDP, ICMP, ARP, Auto-IP, DNS, SNMP v2/v3

LED Indicators
Power/System
Serial Ports (4, 8, 16)
Ethernet – Activity/Link
Physical Dimensions
Size: L x W x H
21 cm (8.25 in) x 19 cm (7.5 in) x 6 cm (2.4 in)
Weight:
16-Port = 0.9 Kg (2.0) lbs
8-port = 0.82 Kg (1.8 lbs)
4-port = 0.8 Kg (1.75 lbs)
Software
• Network Time Protocol(NTP) support
• AES 192 & 256 bit encryption support
• Supports copying port config settings
• Gateway Features – port forwarding,
static routers and DHCP servers

Security
SSL v3, SSH v2 Client & Server – up to 1024-bit certificates
Encryption: AES, 3DES, RC4
Authentication: SHA-1, MD5, Base-64
Management
Lantronix Gateway Central powered by MACH10
Web Browser (SSL option for secure login)
CLI (over Serial Ports, Telnet or SSH)
XML Configuration Records via CLI or FTP
Environmental
Operating Temp: 0°C to +55° C (32°F to 131°F)
Storage Temp: -30°C to +80° C
Relative Humidity: 20% to 90% relative humidity, non-condensing
IP Rating = 20
Power
Input: IEC60320 C14 receptacle without a power switch
100-240 VAC, 50/60 HZ, 0.4A
Power Consumption: 23 Watts Max
Nominal Power: 12 Watts
Mounting
Wall mount
Desktop
Certifications
Emissions:
FCC part 15 Subpart B
EN 60601-1-2: 2007
Industry Canada ICES-003 Issue 4 February 2004
CISPR 22:2005 + A1: 2005 + A2: 2006 ITE
CISPR 11:2003 + A1: 2004 + A2: 2006
VCCI V-3/2010.04
AS/NZS CISPR 22: 2009
EN 55022: 2006 + A1: 2007
EN61000-3-2: 2006 + A1: 2009 + A2: 2009
EN61000-3-3: 2008
Immunity:
EN55024 1998 + A1: 2001 + A2: 2003
EN60601-1-2: 2007
EN61000-4-2: 2009
EN61000-4-3: 2006 + A1: 2008
EN61000-4-4: 2004 + A1: 2010
EN61000-4-5: 2006
EN61000-4-6: 2009
EN61000-4-8: 1994 + A1: 2001
EN61000-4-11: 2004
Safety:
UL 60950-1: 2nd edition; US Safety Standard for Information Technology Equipment
UL 60601-1: 1st edition; US Safety Standard for Medical Electrical Equipment
CAN/CSA-C22.2; No. 60950-1-07: 2nd edition; Canada Safety Standard for Information Technology Equipment
CAN/CSA C22.2; No. 601.1: 1990; Canada Safety Standard for Medical Electrical Equipment
IEC 60601-1: 1998 (2nd edition); International Safety Standard for Medical Electrical Equipment
EN60601-1: 1990 (2nd edition) Medical Electrical Equipment –Part 1: General Requirements for Safety
JIS T 0601-1:1999, Japan Safety Standard for Medical Electrical Equipment
Reach
RoHS
Warranty
2-year Limited

Website

https://www.lantronix.com/products/eds-md/#tab-features

Share this page